Tools & Resources
Install Electrical Wiring to Steel Framing
Earth Installation
Steel frames must be permanently earthed in accordance with local electricity supply authority requirements.
Switch & Power Point Support
Fix backing plates for switches and power points using 25mm galvanized clouts to Boxed Studs or #10-16 x 16 mm wafer head screws to Open Studs.
Electrical Wiring
Electrical wiring is installed through service holes provided in studs and wall plates. To prevent damage to insulation, electrical grommets must first be inserted in service holes to be used for cabling.