Install LYSAGHT NOVALINE® fascia

This page contains information on the installation of LYSAGHT NOVALINE® fascia.

Please be aware that installation of fascia and guttering must be carried out by licensed tradespeople in some Australian states.

Fascia Installation Procedure

Support Spacings

The LYSAGHT NOVALINE® fascia should be supported on rafter clips at 1200mm (maximum) centres for sheet roofing, and 600mm (maximum) centres for tile roofing. Where steel roofing is used, the LYSAGHT NOVALINE® fascia shall not be used as an end span support. If fixing to wood use Type 17 screws.

STEP 1

Attach rafter clip at each end of the run, then run a stringline from end to end of the run. Attach rafter brackets level and in line with the string line.

STEP 2

Hook the fascia horizontally under each end clip, then flip the fascia forward and lever over the top of bracket into the vertical position.

STEP 3

Adjust the fascia to the correct position by sliding it along the brackets then secure intermediate brackets by twisting into fascia first and then connecting to rafters.

STEP 4

Fit the fascia accessories as required (i.e. Corners, End Closers, etc).

 

For information on gutter installation see our page: Install LYSAGHT® Gutters to LYSAGHT NOVALINE® Fascia System