Ultrasonic Testing AS1710

This standard applies to the testing of steel plate for general internal quality, using methods, which specify scanning to a designated scanning system. Quality grading, allows the specification of three quality levels for the body of the plate and one quality level for the edge zone (Levels 1, 2, 3 & E).

BlueScope Steel would normally limit the maximum thickness for Level 1 and 1E to 110mm and levels 2, 2E, 3 and 3E to 150mm for ultrasonic testing of plates. Plate thicknesses above these values should be referred to customer technical services.

Scanning of plate

Level 1 - Scan transverse to rolling direction at intervals of 75mm centres over the entire plate.

Level 2 - Scan transverse to rolling direction at intervals of 100mm centres over the entire plate.

Level 3 - Scan transverse to rolling direction at intervals of 150mm centres over the entire plate.

Edges of plate

Trimmed edges (for all quality levels) are scanned along a continuous band within 25mm of the trimmed edge.

Untrimmed edges - no supplementary scanning is to be carried out along the untrimmed edges. Guarantee of limiting discontinuities in the body of the plate does not include the edge zone within 25mm of the untrimmed edge or half the plate thickness up to a maximum of 50mm.

Evaluation sensitivity

For plate thicknesses > 5mm and < 15mm

The gain required to bring the first back echo to full graticule height.

For plate thicknesses > 15mm and < 40mm

The gain required to bring the second back echo to full graticule height.

For plate thicknesses > 40mm and < 180mm

The gain required to bring the first back echo to full graticule height.

Sensitivity shall be monitored continuously. Any change in testing conditions shall be immediately compensated for by adjusting the gain of the flaw detector to maintain the correct testing sensitivity.

Evaluation

For plate thicknesses
> 5mm and < 15mm - Twin 4 MHz
15mm and < 40mm - Single 4 MHz
40mm and < 180mm - Single 2 MHz

Probes and sensitivities used for plate testing differ from those used in weld testing. Therefore different results can be obtained testing the same material.

Significant discontinuity

Any indication greater than 50% of the reduced first or second back echo is considered significant. When significant discontinuities are found evaluation probes and sensitivities are used.

Evaluation

For plate thicknesses > 5mm and < 15mm

Laminations - Any discontinuity causing total reflection of acoustic energy for a probe movement of 5mm in a direction transverse to the major dimension of the discontinuity.

Cluster - Each area over which the echo amplitude exceeds 50% of the first back echo or reduced back echo. This determination shall be made when the discontinuity echo and the back echo are displayed simultaneously.

For plate thicknesses > 15mm and < 40mm

Laminations - Any discontinuity causing total reflection of acoustic energy for a probe movement of 5mm in a direction transverse to the major dimension of the discontinuity.

Cluster - Each area over which the echo amplitude exceeds 50% of the second back echo or reduced back echo. This determination shall be made when the discontinuity echo and the back echo are displayed simultaneously.

For plate thicknesses > 40mm and < 180mm

Laminations - Any discontinuity causing total reflection of acoustic energy for a probe movement of 5mm in a direction transverse to the major dimension of the discontinuity.

Cluster - Each area over which the echo amplitude exceeds 50% of the first back echo or reduced back echo. This determination shall be made when the discontinuity echo and the back echo are displayed simultaneously.

Maximum Size of Discontinuities

Main Body of Plate
Quality Level Minimum area discontinuity considered (significant discontinuity mm²) Maximum area of any individual laminar discontinuity Maximum total area of discontinuity in any area 1m x 1m mm² Maximum avg. inclusion cluster area per m² of entire plate surface
Lam. Incl. mm² Lam. Incl. mm²
Level 1 500 2000 1000 3000 5000 1500
Level 2 500 2000 3000 10000 16000 6000
Level 3 1000 5000 6000 20000 40000 15000

Plate Edges (trimmed edges only)
Quality Level Min area of discontinuity considered significant discontinuity Maximum length of discontinuity Maximum area of individual discontinuity Maximum avg. length of discontinuity in any 1m length Maximum length of discontinuity per metre of edge length
mm² mm mm² mm mm
Level E 300 50 500 100 50