LYSAGHT®
Home > Brands > LYSAGHT® > Home Improvements
LYSAGHT FLATDEK®
Product Description and Features
LYSAGHT FLATDEK® is a modern long span cladding particularly well suited to many types of home improvement projects such as room additions, carports and awnings. The underside of LYSAGHT FLATDEK® features clean uninterrupted lines, with an attractive gloss finish.
- Pan-fixed roof sheeting for open sided awnings where high degree of weather tightness is not required
- Unique overlapping dovetail ribs can be easily fitted together by hand
- May be used on pitches from as low as 2 degrees (1 in 30)
- The top side finished in Surfmist® COLORBOND® steel. The ceiling side finished in either Dover White or Classic Cream high gloss COLORBOND® steel.
Common Uses of this product
Roofing patios, awnings, carports
Warnings
- Minimum recommended roof pitch is 2 degrees (1 in 30)
- Available in NSW - please Contact Us for availability in other states
- Lead and copper are not compatible with COLORBOND® steel
- Read full details on Guidelines for using COLORBOND® steel & ZINCALUME® steel.
Product Details
Schematic
![]() |
![]() |
Material Specification
- COLORBOND® prepainted steel complying with AS/NZS 2728:Type 4, is made from zinc-aluminium alloy coated steel complying with AS1397-2001, G550 (550MPa minimum yield stress), AZ150 (150g/m2 minimum coating mass) or AZ200 (200g/m2 minimum coating mass), or
- The base metal thickness is 0.42mm
Spanning Tables
The maximum recommended support spacings are based on testing in accordance with AS 1562.1-1992. Design and installation of sheet roof and wall cladding, and AS 4040.1-1992. Resistance to concentrated loads.**
Depending on support spacings used, LYSAGHT FLATDEK® can be installed as either a:
- Light foot traffic roof (incidental maintenance foot traffic acceptable); or
- No foot traffic roof (will not support the weight of a person walking on it), see tables.
The pressure considered is based on a typical awning Cpn=-0.8 and Kl=1.5 adjacent to an enclosed structure.
The tables are based on FLATDEK® fixed to supports of 1.0 mm BMT minimum. For FLATDEK® awnings applications, the awning span is often governed by the capacity of the receiver channel and its connections. This must be considered in the design of any awning system.
| Spans for light foot traffic Maximum support spacings (mm) |
||||
|---|---|---|---|---|
| Span type | Wind Classification to AS 4055 & BCA | |||
| N1 (W28) | N2 (W33) | N3 (W41N) | N4 (W50N) | |
| Single End Internal |
2000 2600 3000 |
2000 2600 3000 |
2000 2600 3000 |
2000 2600 3000 |
| Spans for no foot traffic Maximum support spacings (mm) |
||||
| Span Type | Wind classification to AS 4055 | |||
| N1 (W28) | N2 (W33) | N3 (W41N) | N4 (W50N) | |
Single |
5100* 4800 4800 600 |
5100* 4800 4800 600 |
4500 3700 4450 450 |
3300 3000 3500 400 |
Supports must be not less than 1mm BMT.
* Spans of 5100mm may result in noticable deflections under maximum loads. When deflections need to be considered in designs, reduce these spans to 4800mm.

Lengths
Sheets are supplied custom cut.
Capacity & Load Tables
The limit state wind pressure capacity table can be viewed in the LYSAGHT FLATDEK® brochure. Download LYSAGHT FLATDEK® Roof Cladding for Home Improvements Brochure (614 KB)
This information is suitable for use only in areas where a tropical cyclone is unlikely to occur as defined in AS1170.2-2002.