Product Description and Features

LYSAGHT KLIP-LOK® 406 is a strong, durable and versatile long length roof and wall cladding.  It combines the strength of steel, with smart fluted pans and a lock-action rib design which, together with concealed fastening, enables its use on many applications from low pitched roofs to vertical or as horizontal ribbed walling.

Please Note:  LYSAGHT KLIP-LOK® 406 is only available upon enquiry in some states.  Please consult the availability table below for further details.

  • Concealed fastening (no visible screw heads, no piercing of sheeting reducing possibility of leaks)
  • Available in three thicknesses for maximum versatility
  • You can use KLIP-LOK® 406 on roof pitches from as low as 1 degree (1 in 50) for 0.48 and 0.60mm BMT, and 2 degrees for 0.42 BMT. It can also be used on walls
  • Available in a large range of modern COLORBOND® steel colours.

Common Uses of this product

Roof sheeting, wall cladding.

Warnings

  • Minimum recommended roof pitch is 1 degree for 0.48 and 0.60 mm bmt, 2 degrees for 0.42 BMT
  • Ensure selection of suitable material for environmental conditions for maximum durability
  • Lead, copper, free carbon, bare steel and green or some chemically-treated timber are not compatible with ZINCALUME® steel or COLORBOND® steel
  • Read full details on Guidelines for using COLORBOND® steel & ZINCALUME® steel.

Product Details

Schematic

LYSAGHT KLIP-LOK® 406 Dimensions

Physical Properties

Mass and Yield
Thickness
(mm BMT)
COLORBOND® steel ZINCALUME® steel
kg/m kg/m2 m2/t kg/m kg/m2 m2/t
0.42 2.04 5.03 199 2.01 4.95 202
0.48 2.32 5.71 175 2.28 5.62 178
0.60 2.86 7.04 142 2.82 6.95 144

Tolerances

Length: + 0mm, - 15mm
Width: + 4 mm, - 4mm

Specification

LYSAGHT KLIP-LOK® 406 is made from:

  • ZINCALUME® zinc/aluminium alloy coated steel complying with AS 1397 - 2001 G550, AZ150 (550 MPa minimum yield stress, 150 g/m² minimum coating mass).

    The base metal thickness is 0.42, 0.48 and 0.60mm. or
  • Stainless steel standard grade designation is AISI/ASTM Type 430; UNS No. S43000 available in 0.42 BMT only and is available subject to enquiry.

The COLORBOND® steel complies with AS/NZS 2728 - 1997.

Lengths
Sheets are available custom cut.

Colour Range

LYSAGHT® products are normally available in the standard range of COLORBOND® steel colours. View the standard colour range for:

COLORBOND® steel or
COLORBOND® Ultra and COLORBOND® Stainless steel or
Colour Chart for COLORBOND® Metallic steel

Please check with your local supplier regarding specific colour availability for individual products.

Spanning Tables

The maximum recommended support spacings are based on testing in accordance with AS 1562.1 - 1992, AS 4040.0 - 1992 and AS 4040.1 - 1992.

Roof spans consider both resistance to wind pressure and light roof traffic (traffic arising from incidental maintenance).

Wall spans consider resistance to wind and pressure only.

The pressure considered is based on buildings up to 10m high in Region B, Terrain Category 3, Ms=0.85, Mi=1.0, Mt=1.0 with the following assumptions made:

Roofs:
Cpi=+0.20, Cpe=-0.90, Kl=2.0 for single and end spans, Kl=1.5 for internal spans.

Walls:
Cpi=+0.20, Cpe=-0.65, Kl=2.0 for single and end spans, Kl=1.5 for internal spans.

These spacings may vary by serviceability and strength limit states for particular projects.

Maximum Recommended Support Spacing (mm)
Type of Span Thickness (mm) BMT
0.42 0.48 0.60
Roofs

Single Span
End Span
Internal Span
Unstiffened Eaves Overhang
Stiffened Eaves Overhang

1500
1700
2100
200
600

1800
2400
3000
200
600

2300
2700
3600
300
900
Walls

Single Span
End Span
Internal Span
Overhang

1800
1800
1800
300


2400
2400
2400
400


2700
3000
3000
600

  • For roofs: the data are based on foot-traffic loading.
  • For walls: the data are based on pressures (see wind pressures table).
  • Table data are based on supports of 1mm BMT.

Capacity & Load Tables

The wind pressure capacity table can be viewed in the LYSAGHT KLIP-LOK 406® brochure. Download LYSAGHT KLIP-LOK® 406 (643 KB)

Cyclonic Map

This information is suitable for use only in non-cyclonic areas, that is where a tropical cyclone is unlikely to occur, as defined in AS 1170.2 - 2002**

** More information on the relevant Standards can be found at the Standards Australia Website.

Size Availability

NSW/ACT VIC TAS QLD NT SA WA
Avail. Not Avail.
Avail. By Enquiry* Avail. Not Avail. Avail.

*Please contact our sales office on 13 30 38 for availability

Roof Drainage Capacity

Penetrations will alter the flow of water on a roof. For assistance in design of roofs with penetrations please Contact Us .

Maximum roof lengths for drainage: measured from ridge to gutter (m)
Peak rainfall intensity mm/hr
Roof slope
7.5° 10°
100 375 467 548 682 813 934
150 250 311 365 454 542 623
200 188 234 274 341 406 467
250 150 187 219 273 325 374
300 125 156 183 227 271 311
400 94 117 137 170 203 234
500 75 93 110 136 163 187

Warranty

LYSAGHT® roofing has a material warranty of up to 25 years for corrosion to perforation and a performance warranty of up to 25 years provided it is fixed to specification.

FAQs

  • Can LYSAGHT KLIP-LOK 700 HI-STRENGTH® be side-lapped with LYSAGHT KLIP-LOK® 406?
  • Can LYSAGHT KLIP-LOK® 406 be unclipped?
  • What is cladding and how does it relate to roofing and walling?

 

 
 
Print This PagePrint This Page Email this PageEmail this page